<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>David Swanson Archives | Precision Lubrication</title>
	<atom:link href="https://precisionlubrication.com/author/david-swanson/feed/" rel="self" type="application/rss+xml" />
	<link>https://precisionlubrication.com/author/david-swanson/</link>
	<description></description>
	<lastBuildDate>Mon, 11 Aug 2025 19:12:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://precisionlubrication.com/wp-content/uploads/2022/11/cropped-PLfavicon300-32x32.png</url>
	<title>David Swanson Archives | Precision Lubrication</title>
	<link>https://precisionlubrication.com/author/david-swanson/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Ferrous Debris Measurement Methods That Improve Maintenance</title>
		<link>https://precisionlubrication.com/articles/ferrous-debris-measurement-methods/</link>
		
		<dc:creator><![CDATA[David Swanson]]></dc:creator>
		<pubDate>Wed, 11 Jun 2025 20:28:47 +0000</pubDate>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[Lubricant Analysis]]></category>
		<guid isPermaLink="false">https://precisionlubrication.com/?p=8295</guid>

					<description><![CDATA[<p>The post <a href="https://precisionlubrication.com/articles/ferrous-debris-measurement-methods/">Ferrous Debris Measurement Methods That Improve Maintenance</a> appeared first on <a href="https://precisionlubrication.com">Precision Lubrication</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Ferrous debris refers to small metallic particles, primarily iron, found in lubricating oils and greases caused by <strong>mechanical wear and damage to metal components</strong>. Early detection of this debris is critical, as it can indicate system wear before major damage has time to occur.</p>
<p>Fluid analysis can measure this ferrous debris, so you can catch it early and address the root issue. Are your bearings or gears experiencing fatigue? Is your lubricant sufficient, or is it degraded? Is there an ingress of dirt, water, or other contaminants causing wear?</p>
<h2>From Metal to Metrics: Measuring Ferrous Debris</h2>
<p>Determining the amount of ferrous debris detected in a sample can narrow down what is wearing down to cause these particles and give insights into repairs. Measuring the amount of ferrous debris in an oil sample can be challenging, and analyzing with ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) is limited to particles lower than ~5–10 microns (µm) in diameter.</p>
<p>There are two main methods for measuring larger ferrous debris particles, which can give more insights into particle size: PQ™ (Particle Quantifier) and FerroQ™.</p>
<p>When discussing the differences in measurement and getting a bit technical about the instrument itself, both PQ™ and FerroQ™ measure the magnetic interference of a magnetic field caused by ferrous particles. The difference is that for PQ™, the magnetic field is generated under the oil sample in the bottle (which amounts to only the bottom centimeter or so).</p>
<p>With the FerroQ™ method, the magnetic field surrounds the oil sample as the sample is placed inside the field, analyzing the entire sample, enabling better and more accurate analysis.</p>
<p>Because of this difference in fields used for measurement, the PQ™ system has limitations. When comparing the results, the PQ™ index displayed a skew, most likely due to PQ™ not analyzing the entire sample, as seen in the graph below.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img fetchpriority="high" decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2025/06/pq-vs-ferroq.png" width="687" height="451" alt="PQ vs FerroQ" class="wp-image-8296 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2025/06/pq-vs-ferroq.png 687w, https://precisionlubrication.com/wp-content/uploads/2025/06/pq-vs-ferroq-480x315.png 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 687px, 100vw" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Better Data Starts Here: Say Hello to FerroQ</h2>
<p>As a fluid analysis laboratory, we’re continuously looking to improve our analysis services and help customers make data-driven maintenance decisions. After weighing different test methods of determining the amount of ferrous debris in an oil or grease sample, POLARIS Laboratories® is making the official switch over to reporting results with FerroQ™.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2025/06/ferroq.jpg" width="500" height="525" alt="FerroQ" class="wp-image-8297 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2025/06/ferroq.jpg 500w, https://precisionlubrication.com/wp-content/uploads/2025/06/ferroq-480x504.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 500px, 100vw" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>The Poseidon FerroQ™ instrument represents a better technique and allows us to provide fluid analysis customers with more precise analysis of the test results. Because the FerroQ™ instrument reports its results in ppm, instead of an Index like PQ™, results are quantifiable, NIST (National Institute of Standards and Technology) traceable, and more adequately meet quality standards.</p>
<p>When POLARIS Laboratories® implements this switch in the coming months, instead of reporting results on the PQ™ Index, test results will be displayed in ppm on the sample report. An example of reported FerroQ™ results on a sample report is below.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_5  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img loading="lazy" decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2025/06/report.jpg" width="820" height="509" alt="FerroQ Report" class="wp-image-8299 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2025/06/report.jpg 820w, https://precisionlubrication.com/wp-content/uploads/2025/06/report-480x298.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 820px, 100vw" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_6  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Essentially, when comparing reporting based on PQ™ Index vs. ppm, FerroQ™ test results are about double PQ™.</p>
<h2>New Insights Ahead: Analyzing Samples with FerroQ™</h2>
<p>Switching from PQ™ to FerroQ™ marks a significant advancement in how ferrous debris is measured and reported in fluid analysis. With FerroQ™, we’re not just improving measurement precision, we’re providing more accurate analysis that can identify early signs of wear to prevent unplanned downtime.</p>
<p><em>For more insights into quantifying ferrous debris, methods, reporting, and analysis referenced in this article, read </em><a href="https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/"><strong><em>Assessing Spectroscopic Methods to Analyze Particles: PQ vs. FerroQ</em></strong></a> <em>published February 2024.</em></p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
<p>The post <a href="https://precisionlubrication.com/articles/ferrous-debris-measurement-methods/">Ferrous Debris Measurement Methods That Improve Maintenance</a> appeared first on <a href="https://precisionlubrication.com">Precision Lubrication</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Assessing Spectroscopic Methods to Analyze Particles: PQ vs. FerroQ</title>
		<link>https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/</link>
					<comments>https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/#respond</comments>
		
		<dc:creator><![CDATA[Bryan Debshaw]]></dc:creator>
		<pubDate>Mon, 05 Feb 2024 23:38:49 +0000</pubDate>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[Condition Monitoring]]></category>
		<category><![CDATA[Lubricant Analysis]]></category>
		<guid isPermaLink="false">https://precisionlubri.wpenginepowered.com/?p=7499</guid>

					<description><![CDATA[<p>The post <a href="https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/">Assessing Spectroscopic Methods to Analyze Particles: PQ vs. FerroQ</a> appeared first on <a href="https://precisionlubrication.com">Precision Lubrication</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_1 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_1">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_1  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_7  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Ferrous debris, put simply, refers to the metallic particles or fragments, mainly composed of iron (Fe), within a sample of lubricating oil.</p>
<p>Prematurely identifying ferrous debris can lead to identifying wear and tear within the system – which, when left unresolved, can lead to catastrophic equipment problems.</p>
<p>Determining the amount of ferrous debris in a sample has always been a challenge for condition monitoring laboratories and even at the end-user facilities.</p>
<p>Historically, there have always been challenges with spectroscopic methods not fully analyzing the ferrous debris load; both ICP-OES (Inductively Coupled Plasma &#8211; Optical Emission Spectrometry) and RDE (Rotating Disk Electrode) only fully analyze particles lower than about 10µm in diameter.</p>
<h2>Identifying Ferrous Debris: Considering Two Methods</h2>
<p>In 1985, the Swansea Tribology Centre introduced the solution to this problem: the PQ™ (Particle Quantifier) Ferrous Debris Monitor. Since then, the PQ™ has become an essential component of oil condition monitoring programs and is used in most laboratories specializing in this worldwide.</p>
<p>The PQ™ is a sensitive magnetometer that measures the influence on a magnetic field (known as the Hall effect) that a sample exerts, thus providing a quantitative (though unitless) result of the ferrous wear in the sample. This result can be trended with acceptable linearity over a wide range of ferrous debris concentrations and particle sizes.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_8  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>With all the advantages and benefits of PQ™, some serious limitations exist. PQ™ allows samples to be measured in the bottle, but when doing so, only the bottom centimeter or so is analyzed.</p>
<p>Standards are only available from the manufacturer and are not NIST (National Institute of Standards and Technology) traceable. Finally, there is the issue that the results are unitless – the PQ™ Index is a dimensionless number.</p>
<p>To meet these limitations, newer instruments have been developed. One of which is the new Poseidon FerroQ™. The FerroQ™ uses a set of coil windings, one for measurement and one for reference.</p>
<p>When the sample is inserted, any ferrous material in the oil or grease sample changes the inductance of the measurement coil relative to the reference coil.</p>
<p>A sensitive signal conditioning circuit detects those minuscule changes in the inductance of the measurement coil, and the embedded processor interprets this signal to provide a mass/volume output based on calibration standards.</p>
<h2>Reporting Differences</h2>
<p>Products such as PQ™ devices and some PPM devices often use a single coil below the sample. This results in a device highly sensitive to particles at the bottom of a sample and insensitive to those at the top. FerroQ™ measurement coil surrounds the sample, providing uniform sensitivity and superior repeatability.</p>
<p>Finally, the FerroQ™ reports results in mg/kg and utilizes NIST-traceable standards back to a primary iron standard. This gives a result that is quantifiable and more adequately meets quality standards.</p>
<p>To confirm the traceability and accuracy of the results from the FerroQ™, 0.0151g of Iron Powder, &lt;10 µm, ≥99.9% trace metal basis from Sigma Aldrich was prepared in 10.0007 g total of a UV reactive resin. The theoretical result was 1510 mg/kg.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img loading="lazy" decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2024/02/ferroq-results-1.jpg" width="474" height="147" alt="" class="wp-image-7505 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2024/02/ferroq-results-1.jpg 474w, https://precisionlubrication.com/wp-content/uploads/2024/02/ferroq-results-1-300x93.jpg 300w" sizes="(max-width: 474px) 100vw, 474px" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_10  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Some laboratories desire to switch from the venerable PQ™ to the FerroQ™. To determine this, 1291 comparisons were made.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_11  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img loading="lazy" decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-2.jpg" width="800" height="522" alt="" class="wp-image-7503 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-2.jpg 800w, https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-2-480x313.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_12  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Using all data, results show that above 1000 PQ™ Index, the data did have a skew. This is likely due to the PQ not analyzing the entire sample, only the bottom ~1 cm of the sample.</p>
<p>Removing this data shows a definite correlation between the two methods:</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_13  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p><img loading="lazy" decoding="async" src="https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-trimmed-3.jpg" width="800" height="520" alt="" class="wp-image-7504 aligncenter size-full" srcset="https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-trimmed-3.jpg 800w, https://precisionlubrication.com/wp-content/uploads/2024/02/pq-vs-ferroq-trimmed-3-480x312.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw" /></p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_14  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>In summary, the FerroQ™ technology will perform similarly to the PQ™ technology. This, coupled with the FerroQ™ having NIST traceable standards, reporting in mg/kg, and analyzing the entire sample (as opposed to only the bottom), may be a superior method to the venerable PQ™.</p>
<p>Testing laboratories and end-user facilities can decide what test method and product is used to determine ferrous debris in oil samples, and evaluating benefits, advantages, and limitations must be considered, as well as what reported results are required.</p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
<p>The post <a href="https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/">Assessing Spectroscopic Methods to Analyze Particles: PQ vs. FerroQ</a> appeared first on <a href="https://precisionlubrication.com">Precision Lubrication</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://precisionlubrication.com/articles/analyze-particles-pq-ferroq/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
